DEFINITY® Extender1100 Switch ModuleSystem Administrator’s Guide555-025-114Comcode 108315268Issue 1June 1998

Strany 2

Important Safety InstructionsIssue 1 June 1998 viiThe exclamation point in an equilateraltriangle is intended to alert the user to thepresence of im

Strany 3

Important Safety Instructionsviii Issue 1 June 1998 Use only Lucent Technologies-recommended/approvedDEFINITY ECS accessories. Do not install this

Strany 4 - Contents

Customer Support InformationIssue 1 June 1998 ixSupport Telephone NumberIn the USA only, Lucent Technologies provides a toll-treecustomer Helpline (

Strany 5

Customer Support Informationx Issue 1 June 1998Security of Your System:Preventing Toll FraudAs a customer of new telephone equipment, you should be

Strany 6

Customer Support InformationIssue 1 June 1998 xiThe DEFINITY Extender 1100 System, through properadministration, can help you reduce the risk of un

Strany 7

Customer Support Informationxii Issue 1 June 1998Lucent TechnologiesLimited WarrantyLucent Technologies Inc. warrants this equipment to be free ofde

Strany 8 - 3 Installation

Customer Support InformationIssue 1 June 1998 xiiiFCC Notificationand Repair InformationThis equipment is registered with the FCC in accordance with

Strany 9 - 4 Troubleshooting

Customer Support Informationxiv Issue 1 June 1998 Ringer Equivalence Number (REN). The REN is used todetermine the number of devices that can be co

Strany 10 -  ECS control

Customer Support InformationIssue 1 June 1998 xv Changes at Local Telephone Company. Your localtelephone company may make changes in its facilities

Strany 11 - SAVE THESE INSTRUCTIONS

Customer Support Informationxvi Issue 1 June 1998

Strany 12 - Support Telephone Number

Copyright _ 1998, Lucent Technologies 555-025-114All Rights Reserved Issue 1Printed in USA June 1998NoticeEvery effort was made to ensure that the in

Strany 13 - Security of Your System:

About This BookIssue 1 June 1998 xviiIntended AudienceThis book is intended to help in the installation, systemadministration, and maintenance of th

Strany 14 - Intervention

About This Bookxviii Issue 1 June 1998Terms and ConventionsThe DEFINITY Extender 1101 System is henceforth referred to asthe “Remote Module.”The DEF

Strany 15 - Limited Warranty

About This BookIssue 1 June 1998 xixTypographical ConventionsCertain type fonts and styles act as visual cues to help you rapidlyunderstand the info

Strany 16 - FCC Notification

About This Bookxx Issue 1 June 1998If you have problems with your Switch Module, contact yoursystem administrator. If the problem can not be solved

Strany 17 - Procedures

About This BookIssue 1 June 1998 xxiRelated DocumentsThe documents listed below are part of the DEFINITY ECSdocumentation set. These documents can b

Strany 18 - Information

About This Bookxxii Issue 1 June 1998Document No.TitleDEFINITY Enterprise Communications Server (ECS)System Documents555-230-833 CD-ROM for Mainte

Strany 19 - Issue 1 June 1998

About This BookIssue 1 June 1998 xxiiiHow to Comment on ThisDocumentWe welcome your comments, both positive and negative. Pleaseuse the feedback for

Strany 20 - About This Book

FEEDBACK FORMDEFINITY Enterprise Communications Server (ECS)Title: DEFINITY Extender 1100 System Administrator’sGuideDocument No.: 555-025-114 Iss

Strany 21 - Terms and Conventions

Other _____________________________________________

Strany 22 - How to Use This Book

Issue 1 June 1998 1-1Introduction1An overview of the functioning and specifications of the DEFINITY Extender1100 SystemThe DEFINITY Extender 11

Strany 23 - Product Safety Labels

Industry Canada (IC) Interference InformationThis digital apparatus does not exceed the Class B limits for radio noise emissions set out in theradio i

Strany 24 - Related Documents

Introduction1-2 Issue 1 June 1998System Operation andConfigurationThe DEFINITY Extender 1100 System is designed for use with aDEFINITY ECS of Rele

Strany 25

IntroductionIssue 1 June 1998 1-3The modules communicate via a single two-wire voice-gradecircuit that can extend your DEFINITY ECS telephone to vir

Strany 26 - Document

Introduction1-4 Issue 1 June 1998Equipment ListThe Switch Module comes with most of the necessary equipment.However, some additional items are req

Strany 27

IntroductionIssue 1 June 1998 1-5You must supply the following for installation: DEFINITY ECS two-wire, 24-port TN-2224 circuit pack or theolder TN2

Strany 28 - THIS FORM MAY BE PHOTOCOPIED

Introduction1-6 Issue 1 June 1998NOTES:1. The Class B 8410DR which is identical to the 8410D but isFCC Class B for residential use. The CALLMASTER

Strany 29 - Introduction

IntroductionIssue 1 June 1998 1-7Connecting at rates greater than 19,200 over a lesser quality linewill cause a high bit error rate which could resu

Strany 30 - Configuration

Introduction1-8 Issue 1 June 1998 Table 1-1. Switch Module Specifications Specification Description Size 8” x 8” x 1 ½”(205 mm x 205 mm x 40

Strany 31 - Security Alert:

IntroductionIssue 1 June 1998 1-9 Considerations Keep the following in mind when you use the DEFINITY Extender1100 System: The DEFINITY Extender 110

Strany 32 - Equipment

Introduction1-10 Issue 1 June 1998 ! Security Alert: Using the Remote Module gains access to the features ofthe DEFINITY ECS, including access to

Strany 33 - Compatibility

Issue 1 June 1998 2-1Configuration2 How the system administrator programs the passwords into theDEFINITY Extender 1100 System.Before a Remote Modu

Strany 34 - Specifications

ContentsIssue 1 June 1998 iCustomer Support Information...ix Support Telephone Number...ix Se

Strany 35

Configuration 2-2 Issue 1 June 1998 Each password begins with two digits (00–99). The 00password is reserved for the system administrator and can

Strany 36 - Specification Description

Configuration Issue 1 June 1998 2-3The Switch Module must be connected to the PC or terminal usingan RS-232D serial cable, which connects to the RS

Strany 37 - Considerations

Configuration 2-4 Issue 1 June 1998 The Enhanced Terminal InterfaceThe Enhanced Terminal Interface (ETI) provides you with a user-friendly interf

Strany 38 - 1-10 Issue 1 June 1998

Configuration Issue 1 June 1998 2-53. Press the Enter key, or 1.The following menu is displayed on the screen:1) Passwords2) PBX COM port settings:

Strany 39

Configuration 2-6 Issue 1 June 1998You can select a menu item by: Using a hot key (the number of the menu item). Using the arrow up and arrow d

Strany 40 - Programming the Switch

Configuration Issue 1 June 1998 2-7 Stop Bits

Strany 41

Configuration 2-8 Issue 1 June 1998Setting Data RateTo set the Data Rate:Highlight the Data Rate you want and press Enter. Data Rateoptions are:

Strany 42 - 2-4 Issue 1 June 1998

Configuration Issue 1 June 1998 2-9When you make your selection, the Stop Bits Menu appears.Setting Stop BitsTo change Stop Bits:Highlight the Stop

Strany 43 - The Terminal Edit Line

Configuration 2-10 Issue 1 June 1998 Setting Passwords Before a Remote Module user can communicate with the SwitchModule, the system administrato

Strany 44 - 2-6 Issue 1 June 1998

Configuration Issue 1 June 1998 2-11 NOTE:If more than one Switch Module is connected to the DEFINITYECS in a hunt group configuration, you should

Strany 45 - Stop Bits

Contentsii Issue 1 June 19981 Introduction...1-1 System Operation and Configuration...

Strany 46 - Setting Data Bit

Configuration 2-12 Issue 1 June 1998 character strings associated with you or with the remote user or with your business. These include: —

Strany 47 - Show Settings

Configuration Issue 1 June 1998 2-13 Each password begins with two digits (00–99). The “00”password is reserved for the system administrator and ca

Strany 48 - Setting Passwords

Configuration 2-14 Issue 1 June 19984. Type your system administrator password (the default is00000000) and press Enter. The Password Menu is dis

Strany 49

Configuration Issue 1 June 1998 2-15To disable a password:1. Select Change Password from the Password Menu, andpress Enter.The system prompts you t

Strany 50 - Considerations

Configuration 2-16 Issue 1 June 19981. While online, press HOLD button four times.Disconnect is displayed.2. Press 3 until screen displays Set PB

Strany 51

Configuration Issue 1 June 1998 2-17

Strany 52 - 2-14 Issue 1 June 1998

Issue 1 June 1998 3-1 Installation 3 How to install the DEFINITY Extender 1100 ystem After you have programmed passwords for the Switch Module, y

Strany 53 - Configuring Passwords Online

Installation 3-2 Issue 1 June 1998 Location Requirements To ensure successful operation of the DEFINITY Extender 1100System, place the Switch Mod

Strany 54 - 2-16 Issue 1 June 1998

Installation Issue 1 June 1998 3-3 Wiring Requirements Use twisted-pair cable for all connections. NOTE:Before attaching your DEFINITY Extender 11

Strany 55 - Issue 1 June 1998 2-17

Installation 3-4 Issue 1 June 1998 RS-232D provides for simultaneous RS-232D communicationbetween equipment at the off-premise site and the on-pr

Strany 56 - Installation

ContentsIssue 1 June 1998 iiiConsiderations...2-12Programming Passwords Procedure...

Strany 57 - Electrical Requirements

Installation Issue 1 June 1998 3-5 Following installation, administer the line and station ports that usethe Switch Module according to the instruc

Strany 58 - Wiring Requirements

Installation 3-6 Issue 1 June 1998 ! CAUTION: Connecting the Remote Module to the DEFINITY ECS canresult in damage to the module. Prior to instal

Strany 59 - Installation Procedure

Installation Issue 1 June 1998 3-7 ! CAUTION: Do not plug the A/C adapters into a 240 VAC outlet becauseyou will damage the adapter and the module.

Strany 60 - CAUTION:

Installation 3-8 Issue 1 June 1998The data settings for the Switch Module’s COM port and theRemote Module’s COM port must be the same. The factor

Strany 61 - 3-6 Issue 1 June 1998

Installation Issue 1 June 1998 3-9Hardware Flow ControlThe Switch and Remote Modules use the CTS line for flow control.If the hardware flow control

Strany 62 - Transmission

Installation 3-10 Issue 1 June 1998

Strany 63 - Female Connector on Module

Issue 1 June 1998 4-1 Troubleshooting4 Troubleshooting and LED Activity As with all equipment of a sophisticated nature, occasionally anerror i

Strany 64 - Hardware Flow Control

Troubleshooting 4-2 Issue 1 June 1998 Troubleshooting When an error occurs in the operation of the Switch Module, youshould check for malfunction

Strany 65 - 3-10 Issue 1 June 1998

Troubleshooting Issue 1 June 1998 4-3 If you must contact Lucent Technologies on behalf of the remoteuser, be sure to obtain the serial number foun

Strany 66 - Troubleshooting

Troubleshooting 4-4 Issue 1 June 1998 Table 4-1. LED Power up Sequences LED Sequence DescriptionNo LED blinks Error with hardware or ACadapte

Strany 67 - Troubleshooting

Contentsiv Issue 1 June 1998GL Glossary...GL-1

Strany 68 - LED Sequences

Troubleshooting Issue 1 June 1998 4-5 Table 4-2. LED Power up Verification Sequences LED Sequence DescriptionRapidly blinking Red duringprocess

Strany 69 - 4-4 Issue 1 June 1998

Troubleshooting 4-6 Issue 1 June 1998Table 4-3 shows the LED flashes that may occur on the SwitchModule after the power-up LED sequence.Table 4-3

Strany 70 - LED Sequence Description

Troubleshooting Issue 1 June 1998 4-7RGRG Switch Module has been “Flagged” by remoteuser.

Strany 71 - 4-6 Issue 1 June 1998

Troubleshooting 4-8 Issue 1 June 1998Error MessagesIf a problem has been encountered during the connection process,an error message appears on th

Strany 72 - Issue 1 June 1998 4-7

Troubleshooting Issue 1 June 1998 4-9Table 4-4. Error Messages—ContinuedMessage Cause ActionNo Answer The Switch Module isnot responding. TheRemot

Strany 73 - Error Messages

Troubleshooting 4-10 Issue 1 June 1998 Specific ProblemsProblems may develop with the DEFINITY Extender 1100 Systemwhen connecting. The problems

Strany 74

Troubleshooting Issue 1 June 1998 4-113. Check the LED on the Switch Module and compare it to theLED diagnostic sheet as in Table 4-1. The Switch M

Strany 75 - Specific Problems

Troubleshooting 4-12 Issue 1 June 1998Reporting a FaultySwitch ModuleIn a hunt group operation with multiple Switch Modules being usedby differen

Strany 76

Troubleshooting Issue 1 June 1998 4-13

Strany 77 - Reporting a Faulty

Issue 1 June 1998 GL-1Glossary+12 vdc12 volt direct current.120 VAC120 volt alternating current (North American standard electrical supply).BBaud

Strany 78 - Issue 1 June 1998 4-13

FiguresIssue 1 June 1998 v1 Introduction1-1 System Configuration...1-23 Installation3-1 Switch Module Back Pa

Strany 79 - Glossary

Glossary GL-2 Issue 1 June 1998DDedicated Subscriber LinesCommunication lines (usually twisted pair) that are used to connect on-premise telephon

Strany 80 - GL-2 Issue 1 June 1998

Glossary Issue 1 June 1998 GL-3LLEDLight-emitting diode. A semiconductor diode which emits light when acurrent is passed through it, indicating tha

Strany 81 - Issue 1 June 1998 GL-3

Glossary GL-4 Issue 1 June 1998RRemote ModuleThe DEFINITY Extender 1100 System that connects to the remoteDEFINITY ECS telephone.RS-232D (EIA/TIA

Strany 82 - GL-4 Issue 1 June 1998

Glossary Issue 1 June 1998 GL-59 Position Non-Synchronous Interface Between Data TerminalEquipment and Data Circuit-Terminating Equipment Employing

Strany 83 - Issue 1 June 1998 GL-5

Glossary GL-6 Issue 1 June 1998

Strany 84 - GL-6 Issue 1 June 1998

Tablesvi Issue 1 June 19981 Introduction1-1 Switch Module Specifications.......1-83 Installation3-1 DIP Switch Configuration .