Lucent Technologies Window SLV 9124 Uživatelský manuál Strana 232

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 271
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 231
SNMP MIBs and Traps, and RMON Alarm Defaults
B-13
9124-A2-LB20-00
March 2000
Table B-7. enterprise-Specific Traps and Variable-Bindings (3 of 3)
Trap Possible CauseVariable-Bindings
enterpriseSecondary-
ClockFail(4)
H devLastTrapString
(devHealthAndStatus.-
mib)
Operating software has detected
that the secondary clock source
has failed.
String:
Secondary clock failed.
enterpriseSecondary-
ClockFailClear(104)
Operating software has detected
that the secondary clock source
is operational again.
String:
Secondary clock restored.
enterpriseSelfTest-
Fail(2)
H devLastTrapString
(devHealthAndStatus.-
mib)
Unit has completed
(re)initialization and a hardware
failure was detected.
String:
Self test failed: $s. ($s is the
contents of devSelfTestResult.)
enterpriseTest-
Start(5)
For physical interfaces and
frame relay links:
H ifIndex (RFC 1573)
H .0.0 (placeholder)
H devLastTrapString
(devHealthAndStatus.-
mib
F i l i i (DLCI )
At least one test has been
started on an interface or virtual
circuit.
String:
$testString test started on
$ifString. (e.g., DTE Loopback
test started on Sync Data Port
S01P1.)
enterpriseTest-
Stop(105)
For virtual circuits (DLCIs):
H devFrExtDlciIfIndex
(devFrExt.mib)
H devFrExtDlciDlci
(devFrExt.mib)
H devLastTrapString
(devHealthAndStatus.-
mib
All tests have been halted on an
interface or virtual circuit.
String:
$testString test stopped on
$ifString. (e.g., Disruptive PVC
Loopback test stopped on
DLCI 100 of Sync Data Port
S01P1 frame relay.)
Zobrazit stránku 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 270 271

Komentáře k této Příručce

Žádné komentáře